Olympus NORTEC 2000

(Terug naar Onderhoud)

De Nortec 2000D+ wervelstroomtester biedt een frequentiebereik van 50 Hz to 12 MHz en single of dual frequency operation.

De eenvoudig te gebruiken digitale geleidbaarheid en ondersteuning voor roterende scanner maakt deze tester ideaal voor vele toepassingen in de luchtvaart.

Kenmerken van de NORTEC2000

  • Dimensions
    9.5″ L x 5.5″ W x 3.6″ D(241mm x 140mm x 92mm)
  • Weight
    2000D: 6 lbs. (2.7Kg) with batteries installed.
    2000D+: 4.6 lbs (2.09Kg) with battery installed.
    3.6 lbs. (1.6Kg) without batteries.
  • Display(EL)
    EL (electroluminescent), 4.7″ x 3.5″(5.7″ diagonal) (120mm x 90mm [145mm diagonal])
    active display area. 320 H x 240 V pixel display resolution. 72Hz refresh rate.
  • Display(LCD)
    Monochrome LCD (liquid crystal dis-play), 3.0″ x 3.8″ (4.8″ diagonal)(76mm x 96mm [122mm diagonal]),320 H x 240 V pixel. 72Hz refresh rate. Backlight is adjustable for different viewing conditions.
  • Display(Color LCD)
    Available as option for 2000D+models. Color LCD (liquid crystal display), 3.0″ x 3.8″ (4.8″ diagonal),(76mm x 96mm [122mm diagonal]) 320 H x 240 V pixel. 72Hz refresh rate. Backlight is adjustable for different viewing conditions.
  • OperatingTemp
    -4° to 140° F (-20° to 60° C)
  • StorageTemp
    -40° to +176°F (-40° to +80°C)
  • Power DC
    Two 10.8V DR35 NiMH batteries(2000D) One 10.8V Li-Ion battery(2000D+), optional “D” cell belt pack,or optional external DR35 pack.
  • Power AC
    External charger/adapter. Will fully charge batteries in approximately 6hours and operate the instrument simultaneously. Line voltage 100 to240VAC,47-63Hz.
  • Low Battery
    Front panel display, a warning message indicates less than ½ hour operating time remaining.
  • Operating Time
    8 hours typical at 75°F (24°C) withEL display. 7 hours typical with LCD display. Estimated operating time remaining is indicated by an icon on the status display. With optional belt mounted battery pack, 8 hours typical.
  • Humidity
    MIL-STD-28800 — Safe operation in exposure to Class 3 temperature/humidity environment (-10°C to 55°Cat 95% ±5% relative humidity non-condensing).
  • Altitude(Max.Operating)
    15,000 ft. (4,572 m) above sea level.
  • Altitude(Max. Non-operating)
    40,000 ft. (12,192 m) above sea level.
  • Hazardous Area Operation
    Safe operation in explosive atmosphere as defined by Class 1, Divi-sion 2, Group D, as found in the National Fire Protection AssociationCode 70 (NFPA 70), Section 500 and tested using MIL-STD-810E, Method511.3, Procedure 1.

NORTEC 2000 wordt geproduceerd door:

Stacks Image 2618

-N